R&S ZVL
Programming Examples
Basic Tasks
Operating Manual 1303.6580.32-05
565
CALCulate1:PARameter:SDEFine 'Trc4', 'S22'
CALCulate1:FORMat SMITh
// Smith chart for the active trace Trc4, referenced by the channel
number
//
// Display the new traces in diagram areas no. 2 to 4.
DISPlay:WINDow2:TRACe2:FEED 'Trc2'
DISPlay:WINDow3:TRACe3:FEED 'Trc3'
DISPlay:WINDow4:TRACe4:FEED 'Trc4'
//
//
Check the result on the local screen
// Go to local
SYSTem:DISPlay:UPDate ONCE
//
//
Check the result in the trace manager
// The trace manager gives an overview of the current channel/trace configuration
DISPlay:MENU:KEY:EXECute 'Trace Manager'