R&S ZVL
Command Reference
Instrument-Control Commands
Operating Manual 1303.6580.32-05
394
'S11', ...
Measurement parameter (string variable); see list of in the
CALCulate<Ch>:PARameter:SDEFine
command description.
*RST value
–
SCPI,
Command
Types
Device-specific, with query (see 'S11',... parameter description above).
Example:
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'
Create channel 4 and a trace named
Ch4Tr1
to measure the input reflection
coefficient S
11
.
CALC4:PAR:MEAS 'Ch4Tr1', 'S12'
Change the measurement parameter of the trace and measure the transmission
coefficient S
12
.
CALC4:PAR:MEAS? 'Ch4Tr1'
Query the measured quantity. The response is 'S12'.
CALCulate<Ch>:PARameter:SDEFine '<string>', 'S11' | ... | 'Y-S11' | ... | 'Z-S11' | ...
Creates a trace and assigns a channel number, a name and a measurement parameter to it. The trace
becomes the active trace in the channel but is not displayed.
To display the trace defined via
CALCulate<Ch>:PARameter:SDEFine
, create a window
(
DISPlay:WINDow<Wnd>[:STATe] ON
) and assign the trace to this window
(
DISPlay:WINDow<Wnd>:TRACe:FEED
); see example below.
CALCulate<Ch>:PARameter:MEASure
changes the measurement parameter of an existing
trace.
To select an existing trace as the active trace, use
CALCulate:PARameter:SELect
. You can open the
trace manager (
DISPlay:MENU:KEY:EXECute 'Trace Manager'
) to obtain an overview of all
channels and traces, including the traces that are not displayed.
In FW versions <V1.90, traces created with
CALCulate<Ch>:PARameter:SDEFine
must be
selected explicitly (
CALCulate:PARameter:SELect)
in order to become active traces.
<Ch>
Channel number. <Ch> may be used to reference a previously defined channel. If
<Ch> does not exist, it is generated with default channel settings.
'<string>'
Trace name, e.g. 'Trc4'. See
Rules for trace names
in the
Trace Manager
description.
'S11', ...
Measurement parameter (string variable); see list of parameters below.
*RST value
–
SCPI,
Command
Types
Device-specific, no query.
CALCulate<Ch>:PARameter:MEASure?
'<Trc_name>'
queries the measurement parameter of the trace.
CALCulate<Ch>:PARameter:CATalog?
returns a list of all defined traces.
Example:
CALC4:PAR:SDEF 'Ch4Tr1', 'S11'
Create channel 4 and a trace named
Ch4Tr1
to measure the input reflection
coefficient S11.
DISP:WIND2:STAT ON