![Rohde & Schwarz ZVL series Operating Manual Download Page 538](http://html.mh-extra.com/html/rohde-and-schwarz/zvl-series/zvl-series_operating-manual_1477904538.webp)
R&S ZVL
Command Reference
Instrument-Control Commands
Operating Manual 1303.6580.32-05
523
MHz.
SEGM:FREQ:SPAN?
Query the span of the created segment. The response is
5.0000005.
Note: The frequency range of the sweep segment can be changed via
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STARt and
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STOP
.
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STARt <Start>
Defines the
Start
frequency of sweep segment no. <Seg>.
<Ch>
Channel number.
<Seg>
Sweep segment number.
<Start>
Start frequency of the sweep.
Range [def. unit]
Depending on the instrument model [Hz]. The increment is 0.1 kHz.
*RST value
– (no sweep segment defined after reset)
SCPI, Command
Types
Device-specific, command or query
Example:
SEGM:INS 1MHZ, 1.5MHZ, 111, -21DBM, 0.5S, 0, 10KHZ
Create a sweep segment with a sweep range between 1.0 MHz and 1.5
MHz.
SEGM:FREQ:STAR?
Query the start frequency of the created segment. The response is
1.0000006.
Note:
If the start frequency entered is greater than the current stop frequency
([SENSe<Ch>:]SEGMent<Seg>:FREQuency:STOP), the stop frequency is set to the start
frequency plus the minimum frequency span of 1 Hz.
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STOP <Stop>
Defines the
Stop
frequency of sweep segment no. <Seg>.
<Ch>
Channel number.
<Seg>
Sweep segment number.
<Stop>
Stop frequency of the sweep.
Range [def. unit]
Depending on the instrument model [Hz]. The increment is 0.1 kHz.
*RST value
– (no sweep segment defined after reset)
SCPI, Command
Types
Device-specific, command or query
Example:
SEGM:INS 1MHZ, 1.5MHZ, 111, -21DBM, 0.5S, 0, 10KHZ
Create a sweep segment with a sweep range between 1.0 MHz and 1.5
MHz.