R&S ZVL
Command Reference
Instrument-Control Commands
Operating Manual 1303.6580.32-05
397
Types
Example:
*RST; CALC:RIPP:DATA 1,1500000000, 2000000000,3, 1, 2000000000, 3000000000, 5
Define and enable a ripple limit range in the stimulus range between 1.5 GHz and 2
GHz, assigning a ripple limit of +3 dBm. Define and enable a second ripple limit
range in the stimulus range between 2 GHz and 3 GHz, assigning a ripple limit of
+5 dBm.
CALC:RIPP:DISP ON
Show the ripple limit ranges in the active diagram.
CALCulate<Chn>:RIPPle:DELete:ALL
Deletes all ripple limit ranges.
<Chn>
Channel number used to identify the active trace.
*RST value
–
SCPI,
Command
Types
Device-specific, no query.
Example:
*RST; CALC:RIPP:DATA 1,1500000000, 2000000000,3, 1, 2000000000, 3000000000, 5
Define and enable a ripple limit range in the stimulus range between 1.5 GHz and 2
GHz, assigning a ripple limit of +3 dBm. Define and enable a second ripple limit
range in the stimulus range between 2 GHz and 3 GHz, assigning a ripple limit of +5
dBm.
CALC:RIPP:DEL:ALL
Delete both created ripple limit ranges.
CALCulate<Chn>:RIPPle:DISPlay[:STATe] <Boolean>
Displays or hides all ripple limit lines (including all ranges) associated to the active trace.
<Chn>
Channel number used to identify the active trace.
<Boolean>
ON | OFF - Limit line on or off.
*RST value
OFF
SCPI, Command
Types
Device-specific, command or query.
Example:
*RST; CALC:RIPP:DATA 1,1500000000, 2000000000,3
Define and enable a ripple limit range in the stimulus range between 1.5 GHz
and 2 GHz, assigning a ripple limit of +3 dBm.
CALC:RIPP:DISP ON
Show the ripple limit range in the active diagram.