R&S ZVL
Command Reference
Instrument-Control Commands
Operating Manual 1303.6580.32-05
388
<Mk>
Marker number in the range 1 to 10. For a bandfilter search (
BFILter
) this
numeric suffix is ignored and may be set to any value because the bandfilter
search functions always use markers Mkr1 to Mkr4.
<Boolean>
ON | OFF - Enables or disables the marker tracking mode.
*RST value
OFF
SCPI,
Command
Types
Device-specific, command or query.
Example:
Suppose that the active setup contains an active trace no. 1.
CALC:MARK ON; FUNC:EXEC MAXimum
Create marker no. 1 and assign them to trace no. 1. Activate a maximum search
for marker no. 1.
CALC:MARK:SEAR:TRAC ON
Enable the tracking mode for the created marker.
CALCulate<Chn>:MARKer<Mk>[:STATe] <Boolean>
Creates the marker numbered <Mk> and assigns it to trace no. <Chn>.
<Chn>
Channel number used to identify the active trace.
<Mk>
Marker number in the range 1 to 10. If unspecified the numeric suffix is set to
1.
<Boolean>
ON | OFF - Creates or removes the marker.
*RST value
OFF
SCPI, Command
Types
Device-specific, command or query.
Example:
Suppose that the active setup contains an active trace no. 1.
CALC:MARK ON; MARK2 ON
Create markers 1 and 2 and assign them to trace no. 1. The default position of both markers is
the center of the sweep range.
CALCulate<Chn>:MARKer<Mk>:TARget <numeric_value>
Defines the target value for the target search of marker no. <Mk>, which can be activated using
CALCulate<Chn>:MARKer<Mk>:FUCTion:EXECute TARGet
.
<Chn>
Channel number used to identify the active trace.
<Mk>
Marker number in the range 1 to 10.
<numeric_value>
Target search value of marker no. <Mk>.
Range [def. unit]
Depending on the format of the active trace (
CALCulate<Chn>:FORMat
). For
a dB Mag trace the range is –300 dB to +200 dB, the increment (UP. DOWN)
is 0.1 dB. [dB, deg etc., depending on the trace format]
*RST value
Depending on the trace format; 0 dB for a dB Mag trace.