Command Reference
R&S
®
ZNB/ZNBT
716
User Manual 1173.9163.02 ─ 38
Manual operation:
See
CALCulate<Chn>:EYE:VIEW
<EyeView>
Allows to shorten the calculation chain of the related eye diagram without deactivating
the building blocks at the tail end.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<EyeView>
STIMulus | EMPHasis | JITTer | NOISe | DUT | EQUalization
The rightmost building block that shall be part of the calculation
chain STIMulus > EMPHasis > JITTer > NOISe > DUT > EQUal-
ization.
Note that the selected block must be active, for example
CALCulate1:EYE:VIEW JITTER
requires
CALCulate<Chn>:EYE:JITTer:STATe
ON
.
Conversely, if
CALCulate1:EYE:VIEW
is set to
JITTER
and
subsequently
CALCulate1:EYE:JITTer:STATe
is turned
OFF
, the calculation chain is further shortened to the next active
building block.
Options:
R&S
ZNB/ZNBT-K20
Manual operation:
See
7.3.2.6
CALCulate:FILTer[:GATE]...
The
CALCulate:FILTer[:GATE]...
commands define the properties of the time
gate which is used to optimize the time domain response.
CALCulate:FILTer[:GATE]:TIME:AOFFset
........................................................................ 716
CALCulate<Chn>:FILTer[:GATE]:TIME[:TYPE]
................................................................. 717
CALCulate<Chn>:FILTer[:GATE]:TIME:CENTer
................................................................717
CALCulate<Chn>:FILTer[:GATE]:TIME:DCHebyshev
........................................................ 718
CALCulate<Chn>:FILTer[:GATE]:TIME:SHAPe
.................................................................718
CALCulate<Chn>:FILTer[:GATE]:TIME:SHOW
................................................................. 719
CALCulate<Chn>:FILTer[:GATE]:TIME:SPAN
...................................................................719
CALCulate<Chn>:FILTer[:GATE]:TIME:STARt
..................................................................720
CALCulate<Chn>:FILTer[:GATE]:TIME:STOP
...................................................................720
CALCulate<Chn>:FILTer[:GATE]:TIME:STATe
................................................................. 720
CALCulate<Chn>:FILTer[:GATE]:TIME:WINDow
...............................................................721
CALCulate:FILTer[:GATE]:TIME:AOFFset
<Boolean>
Activates the operating mode where the time gate is moved in the opposite direction
when the "Delay" setting is changed.
SCPI Command Reference