Command Reference
R&S
®
ZNB/ZNBT
714
User Manual 1173.9163.02 ─ 38
CALCulate<Chn>:EYE:NOISe:RMS
<NoiseRMS>
Defines the root mean square (RMS) noise level in the generator simulation of the rela-
ted eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Gaussion noise insertion can be enabled using
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<NoiseRMS>
Default unit: V
Manual operation:
See
CALCulate<Chn>:EYE:NOISe:STATe
<Boolean>
Enables/disables Gaussian noise in the generator simulation of the related eye dia-
gram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
The noise RMS level can be set using
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
*RST:
OFF
Options:
R&S
ZNB/ZNBT-K20
Manual operation:
See
CALCulate<Chn>:EYE:STATe
<Boolean>
Defines whether the active trace in the selected channel shall be represented as an
eye diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
Example:
*RST
// switch trace to to S31 and switch on the eye diagram
:CALCulate1:PARameter:MEASure 'Trc1', 'S31'
CALCulate1:EYE:STATe ON
Options:
R&S
ZNB/ZNBT-K20
SCPI Command Reference