Command Reference
R&S
®
ZNB/ZNBT
1094
User Manual 1173.9163.02 ─ 38
<SweepType>
CW | FIXed | SWEep
SWEep - the full formula is applied. For frequency sweeps, the
command defines a sweep range.
CW | FIXed - the reduced formula with f
b
= 0 is applied; the com-
mand defines a fixed frequency.
*RST:
SWEep
Example:
*RST; FREQ:STAR 1E+9; STOP 1.1E+9
Reset the analyzer (activating a frequency sweep) and set the
sweep range between 1 GHz and 1.1 GHz.
SOUR:FREQ2:CONV:ARB:IFR 2, 1, 1E+9, SWE
Convert the source frequency at test port no. 2 to the range
between 3 GHz and 3.2 GHz.
SENSe:FREQuency:CONVersion:GAIN:LMCorrection ON
Enable the load match correction for all conversion gains.
SENSe:FREQuency:CONVersion?
Query the measurement mode. The response is
ARB
, because
the port frequency definition also activates the arbitrary mode.
SENSe:FREQuency:CONVersion FUND
De-activate the arbitrary mode, cancel the port frequency defini-
tion.
Manual operation:
See
"Frequency conversion formula"
7.3.16.2
SOURce:LPORt...
The
SOURce:LPORt...
commands define the logical port configuration (balanced
ports, renumbered single-ended ports).
.......................................................................................1094
.............................................................................1096
SOURce<Ch>:LPORt<LogPt>
<PhysicalPort>[, <PhysicalPort>]
Assigns the logical port number <LogPt> either to the single-ended physical port
<PhysicalPort1> or to a pair of physical ports <PhysicalPort1>,<PhysicalPort2>, at the
same time defining them as balanced port.
Important:
●
All required logical ports (balanced and single ended) must be created explicitly.
●
A balanced port configuration generally introduces a new set of mixed mode mea-
sured quantities. Therefore the traces must be redefined when a balanced port is
created. To avoid any inconsistencies the analyzer deletes all traces when
SOURce<Ch>:LPORt<LogPt>
is used.
●
For the R&S
ZNB, it is essential to complete the logical port assignment before
defining other port properties such as common or differential mode impedances:
whenever a logical port is created using
SOURce<Ch>:LPORt<LogPt>
, the
parameters of all existing logical ports are reset. For the R&S
ZNBT this is not the
case.
SCPI Command Reference