CONTROL SYSTEM
O— O : Continuity
5. If not as specified, replace the airflow mode
W 6 U 7 4 0 W A L
BLOWER MOTOR REMOVAL/INSTALLATION
1. Disconnect the negative battery cable.
2. Remove the under cover.
3. Remove in the order indicated in the table.
4. Install In the reverse order of removal.
W 6 U 7 4 0 W A N
W6U740W14
1
Connector
2
Screw
3
Blower motor
BLOWER MOTOR INSPECTION
1. Remove the under cover.
2. Disconnect the blower motor connector.
3. Connect battery positive voltage to terminal B and
ground to terminal A of the blower motor and
verify its operation.
W 6 U 7 4 0 W 1 3
n
I— I
n
B
A
W 6 U 7 4 0 W A M
4. If not as specified, replace the blower motor.
0 7 -4 0 -7
Summary of Contents for MX-6 1998
Page 1: ......
Page 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Page 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Page 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...