TROUBLESHOOTING [INSTRUMENTATION/DRIVER INFO.]
Symptom Troubleshooting
1
All meters and gauges (speedometer, tachometer, fuel gauge, water temperature gauge) do not operate
TROUBLESHOOTING HINTS
Malfunction in instrument cluster power supply/ground circuit
© All meters and gauges do not operate
METER 10 A fuse malfunction
ROOM 15 A fuse malfunction
Print plate malfunction
Display unit assembly malfunction
Malfunction in wiring harness between METER 10 A fuse and instrument cluster
Malfunction in wiring harness between ROOM 15 A fuse and instrument cluster
Malfunction in wiring harness between instrument cluster and ground
STEP
INSPECTION
ACTION
Is METER 10 A fuse okay?
W 6 U 9 0 1 W U 0
Yes
Go to next step.
No
Replace fuse after repairing wiring harness.
Is ROOM 15 A fuse okay?
Yes
Go to next step.
No
Replace fuse after repairing wiring harness.
W 6 U 9 0 1 W U 1
Remove meter hood.
Remove instrument cluster.
Measure voltage at terminal 2K at instrument
cluster (14-pin) connector of wiring harness.
Is voltage
B+?
Yes
Go to next step.
No
Repair wiring harness between ROOM 15 A fuse and
instrument cluster.