TROUBLESHOOTING [INSTRUMENTATION/DRIVER INFO.]
8
Ail warning lights do not illuminate with ignition switch at ON (engine stopped)
TROUBLESHOOTING HINTS
Malfunction in instrument cluster power supply
0 Warning lights do not illuminate
• METER 10 A fuse malfunction
• Print plate malfunction
• Malfunction in wiring harness between METER 10 A fuse and instrument cluster
STEP
INSPECTION
ACTION
Is METER 10 A fuse okay?
Yes
Go to next step.
No
Replace fuse after repairing wiring harness.
Remove meter hood.
Remove instrument cluster.
Measure voltage at terminal 3N at instrument
cluster (14-pin) connector of wiring harness.
Is voltage
B+?
Yes
Replace print plate.
a-
0 9-22 INSTRUMENT CLUSTER
DISASSEMBLY/ASSEMBLY
No
Repair wiring harness between METER 10 A fuse and
instrument cluster.
S B
\
3N -tJ _ i_ L _ L i_ ll I I I
I I I I
W 6 U 9 0 1 W V 2
0 9 -0 1 P -1 5