CONTROL SYSTEM
AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION
1. Disconnect the negative battery cable.
2. Remove in the order indicated in the table.
3. Install in the reverse order of removal.
W 6 U 7 4 0 W 1 1
1
Connector
2
Screw
3
Airflow mode actuator
AIRFLOW MODE ACTUATOR INSPECTION
1. Remove the airflow mode actuator.
2. Connect battery positive voltage to terminal B and
ground to terminal D, and battery positive voltage
to terminal D and ground to terminal B of the
airflow mode actuator.
3. Verify that the airflow mode actuator operates as
shown below.
Connection
Movement
B+
GND
B
D
VENT -»DEFROSTER
D
B
DEFROSTER->VENT
I
G
X
C
A
J
H
F
D
B
W6U740WAJ
W 6 U 7 4 0 W 1 2
DEFROSTER
W6U740WAK
4. Check for continuity between the airflow mode
actuator terminals by using an ohmmeter.
BI-LEVEL
HEAT
H EAT/D EF
E
A :
105°
B:
30°
C: 60®
D:
90°
E :120°
0 7 -4 0 -6
Summary of Contents for MX-6 1998
Page 1: ......
Page 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Page 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Page 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...
Page 983: ...SERVICE TOOLS 08 60 SERVICE TOOLS 08 RESTRAINTS S S T 08 60 1 08 RESTRAINTS SST 08 60 1...