EMISSION SYSTEM
AIR FILTER INSPECTION
W 6 U 1 1 6 W 0 4
1. Remove the air filter.
4. If not as specified, replace the air filter.
2. Blow air into port A and verify that air smoothly
flows from port B.
3. Blow air into port B and verify that air smoothly
flows from port A.
TO EVAPORATIVE
PRESSURE CONTROL VALVE INSPECTION
1. Remove the pressure control valve.
2. Attach an air hose to the
SST.
3. Set the
SST
to port A and plug port B as shown in
the figure.
W 6 U 1 1 6 W 0 5
8. If there is no airflow, replace the pressure control
valve.
9. Set the
SST
to port A, C and plug port B as
shown in the figure.
W 6 U 1 1 6 W A 4
4. Verify that there is airflow from port D when
pressure of
+0.98 kPa {+7.4 mmHg, +0.29 inHg}
is applied to port A.
5. If there is no airflow, replace the pressure control
valve.
6. Set the
SST
to port B, C and plug port A as
shown in the figure.
W 6 U 1 1 6 W A 5
7.
Verify that there is airflow from port D when
pressure of
+0.98 kPa {+7.4 mmHg, +0.29 InHg}
is applied to port B, C.
10. Verify that there is no airflow from port D when
pressure of
+0.98 kPa {+7.4 mmHg, +0.29 inHg}
is applied to port A, C.
11. If there is airflow, replace the pressure control
valve.
12. Set the
SST
to port D and plug port B.
13. Verify that there is airflow from port A when
pressure of
+0.98 kPa {+7.4 mmHg, +0.29 inHg}
is applied to port D.
14. If there is no airflow, replace the pressure control
valve.
PLUG
0 1 -1 6 -4
Summary of Contents for MX-6 1998
Page 1: ......
Page 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Page 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Page 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...
Page 983: ...SERVICE TOOLS 08 60 SERVICE TOOLS 08 RESTRAINTS S S T 08 60 1 08 RESTRAINTS SST 08 60 1...