DTC P0743
TCC control solenoid circuit failure during self-test
DESCRIPTION
• Damaged wiring or connectors between torque converter clutch control solenoid valve and powertrain
control module
• Short or open circuit in torque converter clutch control solenoid valve
• Short or open circuit in powertrain control module internal transistors
POSSIBLE
CAUSE
• Damaged wiring or connectors between torque converter clutch control solenoid valve and powertrain
control module
• Short or open circuit in torque converter clutch control solenoid valve
• Short or open circuit in powertrain control module internal transistor
STEP
INSPECTION
ACTION
1
Are powertrain control module and torque
converter clutch control solenoid valve
connections at connector and connector pins
okay?
Yes
Go to next step
No
Repair or replace connector(s), then go to step 7
2
Check NGS tester display
• Connect NGS tester to data link connector
• Are torque converter clutch control solenoid
valve operation and NGS tester display
correct?
xr
0 1 -40B POWERTRAIN CONTROL
MODULE (PCM) INSPECTION [KL]
Yes
Go to step 7
No
Go to next step
3
Check for continuity between terminals of torque
converter clutch control solenoid valve and
powertrain control module
• Disconnect negative battery cable
• Disconnect solenoid connector and powertrain
control module connector
• Is there continuity between terminals?
Yes
Go to next step
No
Repair or replace connectors and wiring, then go to step 7
4
Check for a short circuit between terminals of
torque converter clutch control solenoid and
powertrain control module.
• Disconnect solenoid and powertrain control
module connectors
• Connect ohmmeter between GND and torque
converter clutch control solenoid connector
terminal
• Is continuity present?
Yes
Repair short circuit, then go to step 7
No
Go to next step
5
Measure resistance at torque converter clutch
control solenoid valve terminal
• Disconnect nagative battery cable
• Disconnect solenoid connector
• Is resistance correct?
xr
0 5 -1 7B SOLENOID VALVES INSPECTION
[GF4A-EL]
Yes
Go to next step
No
Replace torque converter clutch control solenoid valve,
then go to step 7
x t
0 5 -1 7B SOLENOID VALVES
REMOVAL/INSTALLATION [G F4A-EL]
6
After diagnostic trouble code has been cleared,
recheck if diagnostic trouble code is shown
cr
0 1 -0 1 B ENGINE ON-BOARD DIAGNOSIS
[KL]
Yes
Return to step 2
No
Problem is a temporary poor connection of wiring or
connectors, and should be investigated further, then go to
next step
7
Erase diagnostic trouble code from memory. Can
code be output after performing “After Repair
Procedure”?
Yes
Go to appropriate inspection procedure
No
Finished
0 5 -0 1 B -1 8
Summary of Contents for MX-6 1998
Page 1: ......
Page 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Page 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Page 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...
Page 983: ...SERVICE TOOLS 08 60 SERVICE TOOLS 08 RESTRAINTS S S T 08 60 1 08 RESTRAINTS SST 08 60 1...