TROUBLESHOOTING [ENGINE CONTROL KL]
DTC
P0400
EGR flow malfunction
DESCRIPTION
• DTC P0400 indicates an EGR valve/flow failure
[Possible Cause]
• Damaged EGR valve
• Damaged PCM
• Damaged EGR boost sensor
• Damaged harness connector
• Damaged EGR boost solenoid valve
• Damaged harness
• Restriction in exhaust system
STEP
INSPECTION
ACTION
1
OUTPUT ALL DTCS
• Verify that EGR boost solenoid valve
connector connection and repair as
necessary.
• Output all continuous memory, key on
engine off (KOEO) and key on engine
running (KOER) self-test DTCs.
o - 0 1 -0 1 B ENGINE ON-BOARD
DIAGNOSIS [KL], Retrieving DTCs
Procedure
•
Are any other DTCs displayed on NGS
tester?
Yes
Go to DTC charts and PROCEED as required.
No
Go to next step.
2
CHECK FOR UNMETERED AIR LEAKS
• Carefully inspect following areas for
potential air leaks:
• Hoses connecting to MAF sensor
component.
• Hoses connecting to throttle body.
• Intake manifold gasket leaks.
• Positive crankcase ventilation (PCV)
disconnected.
• Vacuum lines disconnected.
• Improperly seated engine oil dipstick
and tube.
• Exhaust leaks at flanges and gaskets.
•
Are there any air leaks?
Yes
Air leaks located.
SERVICE source of air leak.
RESET PCM to completely clear DTCs.
tr
After Repair Procedure
COMPLETE OBD II Drive Mode.
RERUN OBD Test.
No
Go to next step.
3
CHECK CYLINDER COMPRESSION
•
Check cylinder compression.
o * 01-10B COMPRESSION INSPECTION
[KL]
• Are cylinder compression readings
within specification?
Yes
Go to next step.
No
SERVICE as necessary.
RESET PCM to completely clear DTCs.
tr
After Repair Procedure
COMPLETE OBD II Drive Mode.
RERUN OBD Test.
4
CHECK OPERATION OF EGR VALVE
• Key on and listen for initialization noise
(clicks) of EGR valve by using screwdriver
or soundscope.
Note
• EGR valve initialization is closing action of
valve observed before and after engine is
started, and when engine is stopped.
• Does EGR valve initialization noise
heard?
Yes
Go to step 9.
No
Go to next step.
5
CHECK POWER CIRCUIT TO EGR VALVE
•
Key off.
•
EGR valve disconnected.
•
Key on, engine off.
•
Measure voltage between power circuit
and chassis ground at EGR valve vehicle
harness connector.
• Is EGR valve power voltage greater than
10.5 volts?
Yes
Go to next step.
No
SERVICE open in EGR valve power circuit.
RECONNECT all components.
RESET PCM to completely clear DTCs.
c
r
After Repair Procedure
COMPLETE OBD II Drive Mode.
RERUN OBD Test.
0 1 -0 1 B -5 7
Summary of Contents for MX-6 1998
Page 1: ......
Page 501: ...STARTING SYSTEM 3 If not as specified replace the starter interlock switch 01 19 3...
Page 803: ...MANUAL TRANSAXLE W 6 U 5 1 5 W A C 05 15 7...
Page 934: ...CONTROL SYSTEM CONTROL SYSTEM STRUCTURAL VIEW W6U740WA0 07 40 2...
Page 983: ...SERVICE TOOLS 08 60 SERVICE TOOLS 08 RESTRAINTS S S T 08 60 1 08 RESTRAINTS SST 08 60 1...