10.2.7
OpenFlow Variant
To configure the OpenFlow variant of switch. It can choose the OpenFlow 1.0 or OpenFlow 1.1 or
OpenFlow 1.2 or OpenFlow 1.3 protocol to connect with Controller.
Syntax
variant { openflow10 | openflow11 | openflow12 | openflow13 }
Default Setting
openflow10
Command Mode
OpenFlow Instance Mode
10.2.8
OpenFlow Fail Mode
To configure the OpenFlow fail mode of connection interruption. It can choose the Fail-Secure or
Fail-Standalone mode.
In the case that a switch loses contact with all controllers, the switch should immediately enter either 3
protocol to connect with standalone modet a switch loses contact with only change to switch behavior
is that packets and messages destined to the controllers are dropped. Flows should continue to expire
according to their timeouts in es destined to the controllers are dropped. Fl the switch processes all
packets using the OFPP_NORMAL port; in other words, the switch acts as a legacy Ethernet switch or
router.
Syntax
failmode { secure | standalone }
Default Setting
secure
Command Mode
OpenFlow Instance Mode