11.4.5.2
Configuring Server Configuration Page
Selection Criteria
Server
Selects the server for which data is to be displayed or configured. If
the add item is selected, a new TACACS server can be configured.
Configurable Data
Server Address
- Specifies the Server IP address or Hostname. Hostnames are
composed of series of labels concatenated with dots. Each label must be between 1 and 63
characters long, and the entire hostname has a maximum of 253 characters.
Priority
- Specifies the order in which the servers are used. Default value is 0. It should
be within the range 0-65535.
Port
- Specifies the authentication port. Default value is 49. It should be within the range 0-65535.
Key String
- Specifies the authentication and encryption key for communications between
the device and the server. The valid range is 0-128 characters. Default is blank. The key
must match the encryption used on the server.
Apply
- Allows you to enter the key in the Key String field. If the checkbox is not checked, you will
not be able to enter the key. By default its unchecked.
Connection Timeout
- The amount of time that passes before the connection between the device
and the server time out. The range is (1 to 30). Default valiue is 5. Enter 0 to set it to
default value.
Command Buttons
Submit
- Send the updated screen to the switch and cause the changes to take effect on the switch
but these changes will not be retained across a power cycle unless a save is performed.
Remove
- Remove the selected server from the configuration.