Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 1287/1568
Idle Timeout
- Enter the number of seconds a user can remain idle before automatically being
logged out. If the value is set to 0, the timeout is not enforced.The default value is 0.
Session Timeout
- Enter the number of seconds to wait before terminating a session. A user is
logged out once the session timeout is reached. If the value is set to 0, the timeout is not enforced.
The default value is 86400 (24 hours).
Max Up Rate
- Enter the maximum speed, in bytes per second, that a client can transmit traffic when
using the captive portal. This setting limits the bandwidth at which the client can send data into the
network.
Max Down Rate
- Enter the maximum speed, in bytes per second, that a client can receive traffic
when using the captive portal. This setting limits the bandwidth at which the client can receive data
from the network.
Max Receive
- Enter the maximum number of bytes that a client is allowed to receive when using the
captive portal. After this limit has been reached the user will be disconnected.
Max Transmit
- Enter the maximum number of bytes that a client is allowed to transmit when using
the captive portal. After this limit has been reached the user will be disconnected.
Max Total
- Enter the maximum number of bytes the user is allowed to transfer (sum of bytes
transmitted and received). After this limit has been reached the user will be disconnected.
User Group
- If the Verification Mode is Local or RADIUS, assign an existing User Group to the
captive portal or create a new group. All users who belong to the group are permitted to access the
network through this portal. The User Group list is the same for all CP configurations on the switch.
Code
- Enter the IANA Language Subtag code for the language. All codes are listed in the IANA
Language Subtag Registry. If the language is currently supported by the switch, the code is filled in
automatically when you select the language.
Language
- To add a captive portal configuration in a language that is supported by the switch, click
the ... button to display and select the language to use for the captive portal.
Command Buttons
Clear
- All configurations will be set to the default values for this CP.
Submit
- Update the switch with the values on the screen. If you want the switch to retain the new
values across a power cycle you must perform a save.
Refresh
- Refresh the data on the screen with the present state of the data in the switch.