Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 89/1568
6.2.3.7
show interface switchport
This command displays VLAN port information.
Syntax
show interface switchport [<slot/port>]
<slot/port> -
Interface number.
no parameter
–
Display the entire table.
Default Setting
None
Command Mode
Privileged Exec
Display Message
Interface:
Indicates by slot id and port number which port is controlled by the fields on this line. It is
possible to set the parameters for all ports by using the selectors on the top line.
Port VLAN ID:
The VLAN ID that this port will assign to untagged frames or priority tagged frames
received on this port. The value must be for an existing VLAN. The factory default is 1.
Acceptable Frame Types:
Specifies the types of frames that may be received on this port. The
options are 'VLAN only' and 'Admit All'. When set to 'VLAN only', untagged frames or priority tagged
frames received on this port are discarded. W hen set to 'Admit All', untagged frames or priority
tagged frames received on this port are accepted and assigned the value of the Port VLAN ID for this
port. W ith either option, VLAN tagged frames are forwarded in accordance to the 802.1Q VLAN
specification.
Ingress Filtering:
May be enabled or disabled. W hen enabled, the frame is discarded if this port is
not a member of the VLAN with which this frame is associated. In a tagged frame, the VLAN is
identified by the VLAN ID in the tag. In an untagged frame, the VLAN is the Port VLAN ID specified
for the port that received this frame. When disabled, all frames are forwarded in accordance with the
802.1Q VLAN bridge specification. The factory default is disabled.
GVRP:
May be enabled or disabled.
Default Priority:
The 802.1p priority assigned to untagged packets arriving on the port.