6.9.1.6
show dot1x client
This command is used to display client information.
Syntax
show dot1x clients [<slot/port>]
<slot/port> -
is the desired interface number.
no parameter -
All interfaces.
Default Setting
None
Command Mode
Privileged Exec
Display Message
Clients Authenticated using Monitor Mode:
Indicates the number of the Dot1x clients
authenticated using Monitor mode.
Clients Authenticated using Dot1x
: Indicates the number of Dot1x clients authenticated using
802.1x authentication process.
Logical Interface
: The logical port number associated with a client.
Interface
: The physical port to which the supplicant is associated.
User Name
: The user name used by the client to authenticate to the server.
Supp MAC Address
: The supplicant device MAC address.
Session Time
: The time since the supplicant is logged on.
VLAN Id
: The VLAN assigned to the port.
VLAN Assigned
: The reason the VLAN identified in the VLAN ID field has been assigned to the
port. Possible values are RADIUS, Unauthenticated VLAN, Monitor Mode, or Default. W hen the
VLAN Assigned reason is Default, it means that the VLAN was assigned to the port because the
P-VID of the port was that VLAN ID.
Session Timeout
: This value indicates the time for which the given session is valid. The time period
in seconds is returned by the RADIUS server on authentication of the port. This value is valid for the
port only when the port-control mode is not MAC-based.
Session Termination Action
: This value indicates the action to be taken once the session timeout
expires. Possible values are Default and Radius-Request. If the value is Default, the session is
terminated and client details are cleared. If the value is Radius-Request, then a reauthentication of