14. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
14 - 35
(b) Temporary stop/restart/remaining distance clear
Transmit the following command, data No., and data during positioning operation to make
deceleration to a stop.
Command Data
No.
Data
[A] [0]
[4] [1]
STOP
Transmit the following command, data No., and data during a temporary stop to restart.
Command
Data No.
(Note) Data
[A] [0]
[4] [1]
GO
Note. "
□
" indicates a blank.
Transmit the following command, data No., and data during a temporary stop to stop positioning
operation and erase the travel remaining distance.
Command
Data No.
(Note) Data
[A] [0]
[4] [1]
CLR
Note. "
□
" indicates a blank.