5. PARAMETERS
5 - 19
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PA13
*PLSS
Command
pulse input
form
_ _ _ x Command input pulse train form selection
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A-phase/B-phase pulse train (The servo amplifier imports input pulses after
multiplying by four.)
Refer to table 5.3 for settings.
0h
_ _ x _ Pulse train logic selection
0: Positive logic
1: Negative logic
Choose the right parameter to match the logic of the command pulse train received
from a connected controller. Refer to POINT of section 3.6.1 for logic of MELSEC
iQ-R series/MELSEC-Q series/MELSEC-L series/MELSEC-F series.
Refer to table 5.3 for settings.
0h
_ x _ _ Command input pulse train filter selection
Selecting proper filter enables to enhance noise tolerance.
0: Command input pulse train is 4 Mpulses/s or less.
1: Command input pulse train is 1 Mpulse/s or less.
2: Command input pulse train is 500 kpulses/s or less.
3: Command input pulse train is 200 kpulses/s or less (available for the software
version A5 or later)
1 Mpulse/s or lower commands are supported by "1". When inputting commands
over 1 Mpulse/s and 4 Mpulses/s or lower, set "0".
Incorrect setting may cause the following malfunctions.
Setting a value higher than actual command will lower noise tolerance.
Setting a value lower than actual command will cause a position mismatch.
1h
x _ _ _ For manufacturer setting
0h
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...