7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 7
(3) Adaptive tuning mode procedure
No
No
Yes
Yes
No
Yes
Execute or re-execute adaptive
tuning in the high accuracy mode.
(Set [Pr. PB01] to "1 _ _ 1".)
In the standard mode
In the high accuracy mode
Execute or re-execute adaptive
tuning in the standard mode.
(Set [Pr. PB01] to "0 _ _ 1".)
Tuning ends automatically after the
predetermined period of time.
([Pr. PB01] will be "_ _ _ 2" or "_ _ _
0".)
Adaptive tuning
Operation
Is the target response
reached?
Decrease the response until vibration
or unusual noise is resolved.
End
Yes
No
No
Yes
Increase the response setting.
Has vibration or unusual
noise occurred?
Has vibration or unusual
noise been resolved?
Using the machine analyzer, set the
filter manually.
Yes
No
Factor
The response has increased to the machine limit.
The machine is too complicated to provide the
optimum filter.
If assumption fails after tuning is executed at a large vibration or
oscillation, decrease the response setting temporarily down to
the vibration level and execute again.
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...