8. TROUBLESHOOTING
8 - 9
No. Name
Detail
No.
Detail name
Stop
Type
(Note 2,
3)
Alarm
deactivation
Alarm code
Alarm
reset
Cycling
the
power
ACD3
(Bit 3)
ACD2
(Bit 2)
ACD1
(Bit 1)
ACD0
(Bit 0)
Alarm
7B.1
Encoder diagnosis error 1
(safety observation function)
DB
7B
Encoder diagnosis
error (safety
observation function)
7B.2
Encoder diagnosis error 2
(safety observation function)
DB
0 1 1 0
7B.3
Encoder diagnosis error 3
(safety observation function)
DB
7B.4
Encoder diagnosis error 4
(safety observation function)
DB
7C
Functional safety
unit communication
diagnosis error
(safety observation
function)
7C.1
Functional safety unit
communication setting error
(safety observation function)
SD
(Note 5)
0 0 0 0
7C.2
Functional safety unit
communication data error
(safety observation function)
SD
(Note 5)
7D
Safety observation
error
7D.1 Stop observation error
DB
(Note 3)
1 1 1 1
7D.2 Speed observation error
DB
(Note 5)
82
Master-slave
operation error 1
82.1 Master-slave operation error 1
EDB
Network module
initialization error
84.1
Network module undetected
error
DB
84
84.2
Network module initialization
error 1
DB
84.3
Network module initialization
error 2
DB
Network module
error
85.1 Network module error 1
SD
85
85.2 Network module error 2
SD
85.3 Network module error 3
SD
Network
communication error
86.1 Network communication error 1
SD
86
86.2 Network communication error 2
SD
86.3 Network communication error 3
SD
8A
USB
communication
time-out error/serial
communication
time-out
error/Modbus RTU
communication
time-out error
8A.1
USB communication time-out
error/Serial communication
time-out error
SD
0 0 0 0
8A.2
Modbus RTU communication
time-out error
SD
8D
CC-Link IE
communication error
8D.1
CC-Link IE communication error
1
SD
8D.2
CC-Link IE communication error
2
SD
8D.3 Master station setting error 1
DB
8D.5 Master station setting error 2
DB
8D.6
CC-Link IE communication error
3
SD
8D.7
CC-Link IE communication error
4
SD
8D.8
CC-Link IE communication error
5
SD
8D.9 Synchronization error 1
SD
8D.A Synchronization error 2
SD
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...