11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 83
The Type E Combination motor controller can also be used instead of a molded-case circuit breaker.
Servo amplifier
Rated input
voltage AC [V]
Input phase
Type E Combination motor controller
SCCR
[kA]
Model
Rated
voltage
AC [V]
Rated current
[A]
(Heater design)
MR-J4-10A(-RJ)
200 to 240
3-phase
MMP-T32
240
1.6
50
MR-J4-20A(-RJ)
2.5
MR-J4-40A(-RJ)
4
MR-J4-60A(-RJ)
6.3
MR-J4-70A(-RJ)
6.3
MR-J4-100A(-RJ)
8
MR-J4-200A(-RJ)
18
MR-J4-350A(-RJ)
25
25
MR-J4-500A(-RJ)
32
MR-J4-60A4(-RJ)
380 to 480
3-phase
480Y/277
2.5
50
MR-J4-100A4(-RJ)
4
MR-J4-200A4(-RJ)
8
MR-J4-350A4(-RJ)
13
MR-J4-500A4(-RJ)
18
MR-J4-700A4(-RJ)
25 25
(2) For control circuit power supply
When the wiring for the control circuit power supply (L11/L21) is thinner than that for the main circuit
power supply (L1/L2/L3), install an overcurrent protection device (molded-case circuit breaker or fuse) to
protect the branch circuit.
Servo amplifier
Molded-case circuit breaker (Note)
Fuse (Class T)
Fuse (Class K5)
Frame, rated current
Voltage AC [V]
Current [A]
Voltage AC [V]
Current [A]
Voltage AC [V]
MR-J4-10A(-RJ)
MR-J4-20A(-RJ)
MR-J4-40A(-RJ)
MR-J4-60A(-RJ)
MR-J4-70A(-RJ)
MR-J4-100A(-RJ)
MR-J4-200A(-RJ) 30 A frame 5 A
240
1
300
1
250
MR-J4-350A(-RJ)
MR-J4-500A(-RJ)
MR-J4-700A(-RJ)
MR-J4-11KA(-RJ)
MR-J4-15KA(-RJ)
MR-J4-22KA(-RJ)
MR-J4-60A4(-RJ)
MR-J4-100A4(-RJ)
MR-J4-200A4(-RJ)
MR-J4-350A4(-RJ)
MR-J4-500A4(-RJ) 30 A frame 5 A
480
1
600
1
600
MR-J4-700A4(-RJ)
MR-J4-11KA4(-RJ)
MR-J4-15KA4(-RJ)
MR-J4-22KA4(-RJ)
MR-J4-10A1(-RJ)
MR-J4-20A1(-RJ) 30 A frame 5 A
240
1
300
1
250
MR-J4-40A1(-RJ)
Note. When having the servo amplifier comply with the IEC/EN/UL/CSA standard, refer to app. 4.
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...