8. TROUBLESHOOTING
8 - 5
No. Name
Detail
No.
Detail name
Stop
Type
(Note 2,
3)
Alarm
deactivation
Alarm code
Alarm
reset
Cycling
the
power
ACD3
(Bit 3)
ACD2
(Bit 2)
ACD1
(Bit 1)
ACD0
(Bit 0)
Alarm
37 Parameter
error
37.1 Parameter setting range error
DB
1 0 0 0
37.2 Parameter combination error
DB
37.3 Point table setting error
DB
39 Program
error
39.1 Program
error
DB
0 0 0 0
39.2
Instruction argument external
error
DB
39.3 Register No. error
DB
39.4
Non-correspondence instruction
error
DB
3A
Inrush current
suppression circuit
error
3A.1
Inrush current suppression
circuit error
EDB
0 0 0 0
3D
Parameter setting
error for driver
communication
3D.1
Parameter combination error for
driver communication on slave
DB
3D.2
Parameter combination error for
driver communication on master
DB
3E
Operation mode
error
3E.1 Operation mode error
DB
3E.6 Operation mode switch error
DB
1 0 0 0
42
Servo control error
(for linear servo
motor and direct
drive motor)
42.1
Servo control error by position
deviation
EDB (Note
4)
0 1 1 0
42.2
Servo control error by speed
deviation
EDB (Note
4)
42.3
Servo control error by torque/
thrust deviation
EDB (Note
4)
Fully closed loop
control error
(for fully closed
loop control)
42.8
Fully closed loop control error
by position deviation
EDB (Note
4)
42.9
Fully closed loop control error
by speed deviation
EDB (Note
4)
42.A
Fully closed loop control error
by position deviation during
command stop
EDB (Note
4)
45
Main circuit device
overheat
45.1
Main circuit device overheat
error 1
SD
(Note 1)
(Note 1)
0 0 1 1
45.2
Main circuit device overheat
error 2
SD
(Note 1)
(Note 1)
46.1
Abnormal temperature of servo
motor 1
SD
(Note 1)
(Note 1)
46.2
Abnormal temperature of servo
motor 2
SD
(Note 1)
(Note 1)
46
Servo motor
overheat
46.3 Thermistor disconnected error
SD
(Note 1)
(Note 1)
0 0 1 1
46.4 Thermistor circuit error
SD
(Note 1)
(Note 1)
46.5
Abnormal temperature of servo
motor 3
DB
(Note 1)
(Note 1)
46.6
Abnormal temperature of servo
motor 4
DB
(Note 1)
(Note 1)
47
Cooling fan error
47.1 Cooling fan stop error
SD
0 0 1 1
47.2
Cooling fan speed reduction
error
SD
50.1
Thermal overload error 1 during
operation
SD
(Note 1)
(Note 1)
50.2
Thermal overload error 2 during
operation
SD
(Note 1)
(Note 1)
50 Overload
1
50.3
Thermal overload error 4 during
operation
SD
(Note 1)
(Note 1)
0 0 1 1
50.4
Thermal overload error 1 during
a stop
SD
(Note 1)
(Note 1)
50.5
Thermal overload error 2 during
a stop
SD
(Note 1)
(Note 1)
50.6
Thermal overload error 4 during
a stop
SD
(Note 1)
(Note 1)
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...