8. TROUBLESHOOTING
8 - 12
No.
Name
Detail
No.
Detail name
Stop
method
(Note 2,
3)
Warning
E0
Excessive
regeneration warning
E0.1 Excessive regeneration warning
E1.1
Thermal overload warning 1
during operation
E1.2
Thermal overload warning 2
during operation
E1.3
Thermal overload warning 3
during operation
E1
Overload warning 1
E1.4
Thermal overload warning 4
during operation
E1.5
Thermal overload warning 1
during a stop
E1.6
Thermal overload warning 2
during a stop
E1.7
Thermal overload warning 3
during a stop
E1.8
Thermal overload warning 4
during a stop
E2
Servo motor
overheat warning
E2.1
Servo motor temperature
warning
E3
Absolute position
counter warning
E3.1
Multi-revolution counter travel
distance excess warning
E3.2
Absolute position counter
warning
E3.4
Absolute positioning counter
EEP-ROM writing frequency
warning
E3.5
Encoder absolute positioning
counter warning
E4 Parameter
warning E4.1
Parameter setting range error
warning
E5
ABS time-out
warning
E5.1
Time-out during ABS data
transfer
E5.2
ABSM off during ABS data
transfer
E5.3
SON off during ABS data
transfer
E6
Servo forced stop
warning
E6.1 Forced stop warning
SD
E6.2
SS1 forced stop warning 1
(safety observation function)
SD
E6.3
SS1 forced stop warning 2
(safety observation function)
SD
E7
Controller forced stop
warning
E7.1
Controller forced stop input
warning
SD
E8
Cooling fan speed
reduction warning
E8.1
Decreased cooling fan speed
warning
E8.2 Cooling fan stop
E9
Main circuit off
warning
E9.1
Servo-on signal on during main
circuit off
DB
E9.2
Bus voltage drop during low
speed operation
DB
E9.3
Ready-on signal on during main
circuit off
DB
E9.4 Converter unit forced stop
DB
EA
ABS servo-on
warning
EA.1 ABS servo-on warning
EB
The other axis error
warning
EB.1 The other axis error warning
DB
EC
Overload warning 2 EC.1 Overload warning 2
ED
Output watt excess
warning
ED.1 Output watt excess warning
F0
Tough drive
warning
F0.1
Instantaneous power failure
tough drive warning
F0.3 Vibration tough drive warning
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...