10. CHARACTERISTICS
10 - 11
352
500
1000
1500
2000
0
0
10
20
30
40
50
60
70
80
90
100
502
72
202
152
Dynamic brake time
constant [ms]
Speed [r/min]
HG-UR series
(b) 400 V class
Speed [r/min]
0
500 1000 1500 2000 2500 3000
1524
5024
1024
524
100
80
60
40
20
0
2024
3524
7024
Dynamic brake time
constant [ms]
0
10
20
30
40
50
60
0
500
1000
1500
2000
6014
8014
25K14
12K14
20K14
15K14
Speed [r/min]
Dynamic brake time
constant [ms]
HG-SR series
HG-JR1000 r/min series
Speed [r/min]
50
0
40
30
20
10
500 1000 1500 2000 2500 3000
0
11K1M4
22K1M4
15K1M4
701M4
70
60
Dynamic brake time
constant [ms]
Speed [r/min]
0
1000 2000 3000 4000 5000 6000
734
1534
5034
1034
534
120
100
80
60
40
20
0
2034
3534
9034
7034
Dynamic brake time
constant [ms]
HG-JR1500 r/min series
HG-JR3000 r/min series
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...