Synergy Q/MD Engineering Manual (v9.1 MD)
Physical Installation • 3–29
4. Echo Connector
One 6-pin RJ-12 Telco connector is provided for daisy-chaining the remote panel to the
next remote Aux panel in line. Refer to the section “
page 4-4 for connection details. Refer to Appendix A
for pinouts.
5. AC Adapter
One AC Adapter (90 - 264 VAC) is provided with each remote Aux panel as a source of
+5 VDC. Please note:
•
90 - 264 VAC adapter, p/n
103-012
” on page 4-4 for connection details.
6. Cable Retainer
Loop the cable from the AC adaptor through the cable retainer on the back on the panel
for better security.
Please note:
•
There are no user-settable jumpers in the Aux panels.
•
Assignable Aux panels are configured using the control panel menu system. A special
programming mode allows you to assign “rights” for each of the available Aux outputs
to an assignable Aux panel.
•
Dedicated Aux panels are also configured using the control panel menu system. A
special programming mode allows you to assign one specific Aux output to each
dedicated panel.
” on page 11-2 for instructions for both assignable and dedicated
Aux panels.
Installation Procedure
Use the following procedure to install remote Aux panels:
1. Install the appropriate panels in the desired locations for your facility.
2. Connect the supplied AC adapter to a suitable source of line voltage.
3. Plug the DC connector into the rear of the remote Aux panel.
4. Repeat steps 2 and 3 for each Aux panel.
This completes the remote Aux panel installation procedure.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...