6–22 • Software Upgrades and Options
Synergy Q/MD Engineering Manual (v9.1 MD)
4. Select the storage device that you want to use to recall the files from as follows:
•
Use the top
knob to select the storage device you want to recall the files from. You
can select between the following:
~
Hard Drive
— This option will allow you to recall the files from the internal
hard drive.
~
USB
— This option allows you to name the files on a USB key plugged into
the switcher panel USB port.
•
If you are recalling from the hard drive, use the
Set Names
knob to select a
Setup
,
or location, from which to recall the files. There are 100 (
00
through
99
) setups
available from which to recall files.
5. Press
Recall
to display the
Disk Recall Menu 1-2
.
Disk Recall Menu 1-2
6. Select the category of registers that you want to store as follows:
•
Press
All
to recall all categories of registers from a storage device.
•
Press
Memories
to recall only
Memory Registers
from a storage device.
•
Press
Custom Controls
to recall only
Custom Control Registers
from a storage
device.
•
Press
Personality
to recall only
Personality Registers
from a storage device.
•
Press
VTR Clips
to recall only
VTR Clip Registers
from a storage device.
•
Press
Installation
to recall only
Installation Registers
from a storage device.
•
Press
3D Sequences
to recall only
3D Sequence Registers
from a storage device.
•
Press
Bus Maps
to recall only
Bus Maps
from a storage device.
This completes the procedure for recalling your setups from a storage device.
Deleting Existing Setups
Switcher file sets that have been copied to an external computer can be deleted to allow for more
storage space for newer setups.
Use the following procedure to delete an existing setup on an external computer:
1. On your computer, open your Web Browser and, in the address bar, type in the IP
address of your switcher to display the
Splash screen
and the
Synergy MD/X Web
Interface Login Window
.
2. In the
Name
field enter the Synergy MD/X Web Interface user name.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...