11–8 • Additional Installation Setups
Synergy Q/MD Engineering Manual (v9.1 MD)
9. Each aux panel can be assigned to all the available aux buses. The aux panel can be set
up for each aux bus in one of three modes. Press the Aux Bus Output buttons on the
Remote Aux Panel repeatedly until the required mode is selected for the aux bus. You
can choose between the following:
•
Off
— The aux panel is not assigned to the selected aux bus. The button is not lit.
•
Regular
— The aux panel is assigned to the selected aux bus, allowing full control.
The button is lit steadily.
•
Follow
— The aux panel is assigned to the selected aux bus, allowing you to view
what crosspoints are selected on that aux bus, but you cannot control the aux bus.
The button is flashing.
10. Press
Accept
on the
Remote Panel Setup Menu
to store the new settings and exit
programming mode.
This completes the procedure for configuring the switcher to communicate with a Remote Aux Panel.