Synergy Q/MD Engineering Manual (v9.1 MD)
SmartConversion™ • 13–5
Cabling Your Conversion Loops
As discussed in the section “
Planning Your Conversion Loops
” on page 13–3, a conversion loop is
created by connecting an up/down converter between an Aux-Bus output and an Input. The video to
be converted is routed out the Aux Bus and into the up/down converter. Once converted to the proper
format, the video is routed back into the switcher via the input.
Use the following procedure to cable a converter loop between your Synergy Q/MD switcher and an
up/down converter:
1. Locate the Aux Bus output on the Q/MD frame that corresponds to your Conversion
Loop Worksheet. Refer to the section “
need information on setting output BNCs as Aux Bus outputs.
Synergy Q/MD Frame - Rear Output Section
2. Connect the Aux Bus output (refer to column 5 of your Conversion Loop Worksheet) to
the input of your up/down converter using industry-standard coaxial cable. Use cabling
techniques in accordance with good engineering practice. Consult the documentation for
your particular up/down converter for information on which port to connect to.
3. Locate the input on the Q/MD frame that corresponds to column 6 on your Conversion
Loop Worksheet.
Synergy Q/MD Frame - Rear Input Section
Connect the output of your up/down converter to the input of the Q/MD frame using
industry standard coaxial cable. Use cabling techniques in accordance with good
engineering practice.
Operating
Tip
You may find it convenient to have your Conversion Loop Worksheet
available as you perform the Conversion Loop cabling.
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
REF
LOOP
LOCK
CPU
(CAN
AD
A) (100-120V~)220-240V~ 47-63Hz 7A 650W
LAN1
10/100 10/100
LAN2
GP I/O
P
ERIPH
1
P
ERIPH
2
P
ERIPH
3
P
ERIPH
4
P
ANEL
USB
LTC
A
B
E
OUT
C
IN
D
IN
PS 2
PS 1
1
2
MAXIMUM
RATING
1950W
MD L
IVE
P
R
ODUCTION
ENGINE
Output BNCs
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
REF
LOOP
LOCK
CPU
100-120V~ 220-240V~ 47-63Hz
9A 650W (Canada 120V~onl
y)
LAN1
10/100 10/100
LAN2
GP I/O
P
ERIPH
1
P
ERIPH
2
P
ERIPH
3
P
ERIPH
4
P
ANEL
USB
LTC
A
B
E
OUT
C
IN
D
IN
PS 2
PS 1
1
2
MAXIMUM
RATING
1950W
MD L
IVE
P
R
O
DUCTION
ENGINE
Input BNCs
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...