6–14 • Software Upgrades and Options
Synergy Q/MD Engineering Manual (v9.1 MD)
that the upgrade has completed. If the MLE is not passing video properly, check the
System Information Page
again to ensure all items are done.
4. Locate the two small holes on the front edge of the
Video Processor Board
, near the
extractor tabs. If you wish, you can further secure the board by threading tie wraps
through these holes and fastening them around the extractor tabs.
5. Repeat this procedure for all remaining
Video Processor Boards
.
This completes the procedure for re-seating and upgrading the Video Processor Boards. Next you
must re-seat any Squeeze & Tease Carriers. If you do not have any Squeeze & Tease Carriers, proceed
to reboot the switcher. Refer to the section “
Rebooting the Switcher After an Upgrade
Re-seat and Upgrading the Squeeze & Tease Carriers
After the Video Processor Boards have been re-seated and upgraded, you must propagate the upgrade
to all of the Squeeze & Tease Carriers, one at a time. If you do not have any Squeeze & Tease Carriers,
proceed to reboot the switcher. Refer to the section “
Rebooting the Switcher After an Upgrade
Use the following procedure to re-seat and upgrade the Squeeze & Tease Carriers:
1. Gently push the
Squeeze & Tease Carrier
into the slot. When the board stops sliding
freely, push firmly to seat the board, and secure it with the ejector tabs.
Figure 6.3
Power Connector Blade Inspection
2. The switcher upgrades the board you have installed. Refresh the
System Information
Page
until all the
Squeeze & Tease Carrier
functions, and any
Squeeze & Tease
WARP Card
functions, and
Squeeze & Tease DSP Card
functions,
have
Done
as their
Status
.
Important
If there is significant resistance when seating the board, remove the
board from the frame and inspect the connectors for bent pins or other
damage to the connectors (
Important
If the blades in the power connectors are bent or damaged, contact
Ross Video Technical Support. Do not attempt to install a damaged
board.
Power Connector Blades
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...