Synergy Q/MD Engineering Manual (v9.1 MD)
BNC Configuration and Check • 7–15
3. Assign the Still-Store channel that you want to use for the alpha signal to the Still-Store
channel with the fill signal as follows:
•
Use the
BNC
knob to select the Still-Store channel that will have the fill signal.
This will be the Global-Store or MLE-Store channel that you will load the still into.
•
Use the
Alpha
knob to select the Still-Store channel that will have the alpha signal.
This will be the Global-Store or MLE-Store channel that the alpha will be loaded
into.
4. Press
HOME
to display the
Installation Change Confirmation Screen
.
5. Accept or reject the changes you have made as follows:
•
Press
Confirm
to accept the changes.
•
Press
Cancel
to exit the menus safely, without making any changes. The system
returns to the previously stored settings.
This completes the procedure for setting up a Still-Store Auto Key.
Setting Up N/S Disable
The
N/S Disable
Menu
gives the user the option to disable the non-sync indicators for selected BNCs,
if desired. When a BNC has the
N/S Disable
set to
ON
, the non-sync indicator on the panel will not
light for this BNC, even if this source is mistimed.
Use the following procedure to disable the non-sync indicators:
1. Navigate to the
BNC Menu 2-3
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Installation
B
BNC
B
MORE
.
2. Press
N/S Disable
to display the
N/S Disable Menu
.
BNC — N/S Disable Menu
3. Use the
BNC
knob to select the Input BNC that you want to turn the
N/S Disable
feature
On
or
Off
for.
4. Use the
N/S Disable
knob to turn the Non-Sync Disable feature On or Off as follows:
•
OFF
— Select this option if you want to turn the N/S Disable feature
Off
. When the
feature is turned off, the switcher will use the
N/S
indicators on the control panel to
show when a source selected on that bus is out of sync with the switcher.
•
ON
— Select this option if you want to turn the N/S Disable feature
On
. When the
feature is turned on, the switcher will not indicate if the source selected on a bus is
out of sync with the switcher.
5. Use the
N/S Control
knob to select between the following:
•
Individual
— Select this option to turn the N/S Disable feature On or Off for the
selected Input BNC only.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...