Synergy Q/MD Engineering Manual (v9.1 MD)
Custom Controls • 10–31
•
Press
Insert
insert the selected command into the custom control and display the
Insert Special Menu
.
5. Press
UP ONE
to display the
Custom Controls Menus
.
6. Press
Finish Recording
on the
Custom Control Menu 1-2
to finish recording to the
custom control. The custom control button stops flashing.
This completes the procedure for inserting a Loop Custom Control command into a custom control.
Stop Other Custom Controls
The Stop Other Custom Control command allows you place a command in a custom control that will
stop all other running custom controls, except the one the command is in. This can be used to stop
other looping custom controls at a specific point.
Use the following procedure to insert a Stop Other command into a custom control:
1. Navigate to the
Custom Controls Menus
as follows:
•
Press
HOME
B
Custom Controls
.
2. Select the custom control button you want to record to.
3. Press
Start Recording
B
Insert Special
B
Special
.
4. Insert a Stop Other command into the custom control as follows:
•
Use the
Function
knob to select
Stop Other CC
.
•
Press
Insert
to insert the selected command into the custom control and display the
Insert Special Menu
.
5. Press
UP ONE
to display the
Custom Controls Menus
.
6. Press
Finish Recording
on the
Custom Control Menu 1-2
to finish recording to the
custom control. The custom control button stops flashing.
This completes the procedure for inserting a Stop Other command into a custom control.
Custom Control Holds
Use the
Custom Control Hold
feature to place “holds” within a custom control sequence. When
entered, these holds specify a point to stop and wait for a user button-press (of the same custom
control) or an external trigger (Editor or GPI). The macro then executes from that point until it reaches
its end or another embedded hold.
The
Hold CC
allows the user to manually determine in real time, how long a macro is stopped. For
example, a macro is initiated by the operator and when it reaches the
Hold CC
, it stops playing. The
operator then waits until the interview (or whatever) is finished, presses the macro button again, and
the macro resumes playing.
Use the following procedure to place a
Hold CC
within a custom control sequence:
Note
You must insert a
Pause CC
, or
Hold CC
, command into the Looping
Custom Control in order for it to loop properly. Refer to the section
“
” on page 10-34 for more information on
inserting a
Pause CC
command.
Note
A hold is automatically inserted when you perform a Still-Store
capture during the recording of a custom control.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...