8–18 • Output Configuration
Synergy Q/MD Engineering Manual (v9.1 MD)
Use the following procedure to select the MLEs that you want to fade to black:
1. Navigate to the
Output Menu 1-2
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Installation
B
Output
.
2. Press
Fade To Black
to display the
Fade To Black Menu
.
Fade To Black Menu
3. Toggle the desired MLEs
On
or
Off
, as required.
This completes the procedure for selecting the MLEs that you want to fate to black.
MLE Tally Setup
The
MLE Tally
feature allows you to force a selected MLE to always function as if it is on air,
regardless of whether or not it is re-entered on the
Program/Preset Bus
. For instance, you may wish
to send the output of MLE 1 to an external device, such as a VTR, while the Program/Preset bus is on
air. In this configuration, you may want both MLE 1 and the Program/Preset Bus to be tallied. To
achieve this, the
MLE Tally
feature must be used.
Use the following procedure to select the desired tally function for an MLE:
1. Navigate to the
Output Menu 1-2
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Installation
B
Output
.
2. Press
MLE Tally
to display the
MLE Tally Menu
.
MLE Tally Menu
3. Use the
MLE
knob to select the MLE for which you want to assign a tally function.
4. Use the
Tally
knob to select the desired tally function:
•
Always
— Select this option to tally the selected MLE regardless of what is
selected on the
Program/Preset Bus
. The red
ON
LED will always be lit, and all
sources selected on the MLE will tally accordingly. Use this selection for
dual-aspect ratio configurations, as discussed above.
•
On Air
— Select this option when you want an MLE to be tallied only when it is
selected on the
Program/Preset Bus
.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...