13–10 • SmartConversion™
Synergy Q/MD Engineering Manual (v9.1 MD)
Activating Conversion Loops
Each Conversion Loop must be activated in order for SmartConversion to use it.
Use the following procedure to activate a Conversion Loop:
1. Navigate to the
SmartConversion Menu
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Installation
B
Aux Bus
B
SmartConversion
.
2. Press
Aux To Converters
to display the
Aux To Converters Menu
.
Aux To Converters Menu
3. Mark an Aux Bus as being used for SmartConversion as follows:
•
Use the
Aux Bus
knob
to select an Aux Bus you have cabled and configured as
being part of a Conversion Loop.
•
Use the
Used For Converter
knob to select whether the specified Aux Bus is to
be used for SmartConversion. You can select from the following:
~
Yes
— The specified Aux Bus output is attached to an up/down converter and
is to be used for SmartConversion
~
No
— The specified Aux Bus output is not to be used for SmartConversion.
•
Use the
Delay in Fields
knob to specify the delay (in fields) that the up/down
converter adds to the video stream. You can specify a delay of 0-60 fields. See your
up/down converter documentation for the appropriate value.
The middle portion of the menu screen shows a summary of your settings. As you use
the
Aux Bus
knob to scroll through the various Aux Buses, their settings will be
displayed in this area of the menu screen.
4. Repeat steps 1-3 for each conversion loop you have cabled and configured.
This completes the procedure to activate a Conversion Loop.
Selecting Output Video Formats of External Converters
The final step in the Conversion Loop definition process is to define the video formats that each
up/down converters provide as output. You must manually set each up/down converter to output the
desired video format and then specify that same output video format to your Synergy Q/MD switcher
Installation
Tip
You may find it convenient to have your
Conversion Loop
Worksheet
available as you perform the Conversion Loop cabling.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...