Synergy Q/MD Engineering Manual (v9.1 MD)
Physical Installation • 3–5
Synergy 1 Control Panel Connectors
Synergy 1 Control Panel — Rear View, Connector Section
1. Primary Power Inlet
One AC connector is provided for
PRIMARY POWER
on the control panel. It
includes a power lock which is designed to retain the cable.
2. Primary Power Switch and Fuse
One
SWITCH
and
FUSE
assembly is provided for primary control panel power. The
fuse rating is screened adjacent to the fuse holder.
3. Redundant Power Inlet
One AC connector is provided for the optional
REDUNDANT POWER
on the control
panel. It includes a power lock which is designed to retain the cable. The connector is
always installed, whether or not you have the
Redundant Power Supply
option
mounted inside the panel.
4. Redundant Power Switch and Fuse
One
SWITCH
and
FUSE
assembly is provided for redundant control panel power. The
fuse rating is screened adjacent to the fuse holder.
5. Frame Connector
One 8-pin shielded RJ-45 connector (
FRAME
) is provided for communications
between the frame (
PANEL
connector) and the
Synergy 1
control panel.
6. Remote Control Connectors
Five 9-pin “D”
REMOTE
connectors (RS-422) are provided for serial communication
with peripheral devices such as VTRs, disk recorders, video servers or other serial
controlled devices.
1) Primary Power Inlet
2) Primary Power Switch and Fuse
3) Redundant Power Inlet
4) Redundant Power Switch and Fuse
5) Frame Connector
6) Remote Control Connector
7) PS/2 Keyboard Connector
8) Tally Connector
Important
The cable for connecting the Synergy Control Panel to the Synergy
Frame is
not
wired as a standard CAT5 ethernet cable. If you need a
cable of a specific length, contact your Ross Video Representative for
ordering information.
Note
You must use
Remote 5
with a
RJ-12 to DB9 Male Adaptor
to
connect a remote Aux Panel to the
Synergy 1
control panel. If you
intend to connect a Remote Aux Panel to the switcher, you will have to
leave the Remote 5 port open.
FRAME
REMOTE 1 REMOTE 2 REMOTE 3 REMOTE 4 REMOTE 5
TALLY
1
2
4
5
7
8
6
3
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...