3–14 • Physical Installation
Synergy Q/MD Engineering Manual (v9.1 MD)
•
Connect the
PRIMARY POWER
connector to an AC outlet.
•
If the
Redundant Power Supply
option is installed, connect the
REDUNDANT
POWER
connector to an AC outlet.
This completes the control panel installation.
Installing the Electronics Frame
The electronics frame is designed to be rack mounted. Note the following installation requirements:
•
Rack Units
: 3 RU
•
Height
: 5.25 inches (13.34 cm)
•
Depth
: 25 inches (63.5 cm)
•
Rack
: standard 19 inch wide equipment rack
Install the frame for maximum stability during operation and, if possible (but not required) leave a
1RU space above the frame to facilitate installation and removal of the frame door. The frame should
be stalled in an accessible, dry, and dust free location.
To ensure maximum stability, the Synergy Q/MD frame is mounted to the rack using two support
brackets that are located at the rear of the frame. These brackets are included in your Installation Kit.
Use the following procedure to secure the support brackets to the frame:
1. Remove the front door from the frame. Refer to the section “
” on page 3-16 for more information.
2. Remove the support brackets from the Installation Kit that you received with your
shipment.
3. Using standard rack mounting screws (not supplied), attach the support brackets to the
Rear Panel Mounting Flange as per the following diagram. The support brackets are
adjustable, for your convenience.
Caution
Refer to the section “
Important Regulatory and Safety Notices to
Service Personnel
” on page 2-3 for important safety information.
Note
For control panel redundancy, it is recommended that two independent
AC sources be used to feed the control panel power supplies.
Caution
Ensure that you leave space around the electronics frame for adequate
ventilation. Both sides of the frame must be kept clear so that switcher
airflow is not restricted in any way. Failure to provide adequate
ventilation could result in overheating and damage to your switcher
may occur.
Notice
Failure to install the support brackets as instructed will void the
warranty.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...