Synergy Q/MD Engineering Manual (v9.1 MD)
Preliminary Cabling and Video Installation • 4–5
Remote Aux Panel Interconnection — Synergy 2 and 2.5 Control Panels
Use the following procedure to install the control cables between the control panel and each remote
Aux panel:
1. Ensure that you have the correct
6-pin
shielded Telco cable, with a
6-pin RJ-12
connector at each end.
2. Connect a 6-pin shielded Telco cable (of the supplied or custom length) between the
AUX 1
connector on the control panel and the connector labelled
MAIN
on the rear of
the
first
Aux panel in line.
3. To daisy-chain additional Aux panels (up to
8
), connect a 6-pin shielded Telco cable
between the Aux panel connector labeled
ECHO
and the connector labeled
MAIN
on
the
next
Aux panel in line.
4. Repeat step 3 for all additional Aux panels in the
AUX 1
daisy-chain (up to the
maximum of
8
panels per chain).
This completes the procedure for installing the control cables of a Remote Aux Panel to the Synergy
Q/MD control panel. Repeat this procedure to connect additional Remote Aux Panels to the
AUX 2
port.
Synergy 1 Q/MD Remote Aux Panel Cabling
Unlike the
Synergy 1.5, 2
and
2.5 Q/MD
Switchers
, the
Synergy 1 Q/MD
does not have a dedicated
AUX
port. Instead, the provided
RJ-12 to DB9 Aux Adapter
must be installed and setup in the
Remote 5
port on the rear of the control panel in order to connect a
Remote Aux Panel
to the
switcher.
Synergy 1 Q/MD Remote 5 Port Setup
Use the following procedure to assign the Remote 5 port on the rear of the
Synergy 1 Q/MD
control
panel to an Aux port:
1. Navigate to the
Communications Menu 1-2
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Installation
B
Communications
.
Remote Aux Panel
To connector J5 on
the next Aux Panel
in the chain, or no
connection if the last
panel in the chain.
Remote Aux Panel
8
1
2
3
4
7
6
5
4
3
2
1
REMOTE
TALLY
2
1
FRAME
AUX
Synergy Control Panel
To connector J5 on
the next Aux Panel
in the chain, or no
connection if the last
panel in the chain.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...