Synergy Q/MD Engineering Manual (v9.1 MD)
Physical Installation • 3–7
3. Tally Connectors
Four 25-pin “D” connectors are provided for tallies.
•
The functionality of connectors
1
and
2
is standard, providing 36 tally relays.
•
The functionality of connectors
3
and
4
is optional, providing an additional 36 tally
relays. The
Extended Tallies
option must be installed.
The next figure illustrates the dual power connectors on the rear of the
Synergy 3
control panel. The
labeling and placement of these two connectors will differ, depending upon the size of your specific
Synergy Q/MD switcher.
Synergy 3 Control Panel — Rear View, Power Section
Please note:
•
Each AC connector includes a power lock to retain the power cable connector.
The connector marked
REDUNDANT POWER
is always installed, whether or not you have the
Redundant Power Supply
option mounted inside the control panel tub.
Synergy Q/MD Frame
The following figure illustrates the rear connector panel of the electronics frame.
Synergy Q/MD Frame — Rear View
1. Power Connectors
Two AC connectors are provided for frame power. Note that the Synergy Q/MD frame
comes standard with one AC power supply, which is factory-installed in the top slot.
Refer to the section “
” on page 3-25 for complete
instructions on connecting your AC power sources. Refer to Chapter 16, “
Power
Supplies and Fans
” for full details on the power supplies and indicators.
1) Power Connectors
2) Input Section (Slot E not used on MD)
3) Output Section
4) LAN Connectors
5) GP I/O Connector
6) Peripheral 1 - 4 Connectors
7) Panel Connector
8) USB Ports
9) Time Code Input
8
1
2
3
4
7
6
5
4
3
2
1
REMOTE
TALLY
2
1
FRAME
AUX
Primary
Power
Redundant
Power
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
REF
LOOP
LOCK
CPU
100-120V~ 220-240V~ 47-63Hz 9A 650W (Canada 120V~onl
y)
LAN1
10/100 10/100
LAN2
GP I/O
P
ERIPH
1
P
ERIPH
2
P
ERIPH
3
P
ERIPH
4
P
ANEL
USB
LTC
A
B
E
OUT
C
IN
D
IN
16
15
14
13
12
11
10
9
8
7
6
5
4
3
1
2
IN
PS 2
PS 1
1
2
MAXIMUM
RATING
1950W
QMD L
IVE
P
R
ODUCTION
ENGINE
1
2
3
9
8
7
5
6
4
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...