Synergy Q/MD Engineering Manual (v9.1 MD)
Basic Communications Setup • 9–19
Device Selection — Communications Menu 1-2
4. Select the UMD Input protocol for the UMD Input communications port as follows:
•
Use the
Device
knob to select the type of UMD Input you want to assign to the
selected port. You can choose between the following:
~
TSL UMD
— Select this option to assign the native
Television Systems
Limited (TSL) UMD
protocol to the selected port.
5. Press
Com Type
.
Com Type — Communications Menu 1-2
6. Select the type of serial communications that is used to communicate with the UMD
Input device as follows:
•
Use the
Type
knob to select
RS-422
.
7. Press
Com Settings
.
Com Settings — Communications Menu 1-2
8. Set the communications protocols for the UMD Input device as follows:
•
Use the
Baud
knob to
select
38400
.
•
Use the
Parity
knob to select
EVEN
.
9. Press
HOME
to display the
Installation Change Confirmation Screen
.
10. Accept or reject the changes you have made as follows:
•
Press
Confirm
to accept the changes.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...