10–14 • Custom Controls
Synergy Q/MD Engineering Manual (v9.1 MD)
feature is turned off, inserting a Run Custom Control command ends the recording, and
playing, of the first custom control. Refer to the section “
” on page 10-16 for information on running multiple custom controls. If a
custom control starts multiple custom controls, you must stop each one individually, or
use the
Stop Other Custom Control
command.
•
You can run multiple custom controls at the same time by pressing the corresponding
custom control button. If a custom control is already running, pressing the button again
will stop it.
•
You can insert a
Select Custom Control Bank
command into a custom control that will
select a different custom control bank when the custom control is done. To insert the
Select Custom Control Bank
command into a custom control, double-press the custom
control button for the bank you want to select as you are recording the custom control.
This will end the recording of the custom control. A custom control can have only one
Select Custom Control Bank
or
Run Custom Control
command.
Relative Custom Controls
Relative Custom Controls store the MLE re-entry position so that they can be taken on-air from any
MLE that is re-entered on the
PGM/PST MLE
. For example, if you have
MLE 2
re-entered into
MLE 3
(
Configuration 1
), of a Synergy 2.5 Q/MD switcher, and Record a Custom Control on
MLE
2
, you can only recall that custom control on
MLE 2
, in the same configuration. If, however, you have
MLE 1
re-entered into
MLE 3
(
Configuration 2
), the Relative Custom Control will be recalled on
MLE 1
.
Relative Custom Controls are not MLE specific, as normal custom controls, but instead are re-entry
specific. This means that the re-entry order, or levels that the Relative Custom Control was recorded
on, do not need to be the same in order to recall that custom control. For example, if we again record a
Relative Custom Control on
MLE 2
, of a Synergy 2.5 Q/MD, which is re-entered into
MLE 3
(
Configuration 1
), we can recall that Relative Custom Control with more or fewer MLEs. If we have
MLE 1
re-entered into
MLE 2
and
MLE 2
re-entered into
MLE 3
(
Configuration 3
), the Relative
Custom Control will be recalled on
MLE 1
. If we have no MLEs re-entered, (
Configuration 4
) the
Relative Custom Control will be recalled on
MLE 3
.
Important
Relative Custom Controls can only be
properly
recorded and recalled
on upper MLEs that are re-entered onto the PGM/PST MLE. If the
MLE is not re-entered, you will not be able to
properly
record or recall
a relative custom control. Instead, the relative custom control will act
like a normal custom control when recalled.
MLE 2
MLE 3
On-Air
Configuration 1
MLE 1
Configuration 2
MLE 3
On-Air
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...