Synergy Q/MD Engineering Manual (v9.1 MD)
SmartConversion™ • 13–15
~
MLE 2 Util
— The specified up/down converter is locked to the Utility 1
Video + Alpha bus pair on MLE 2.
~
MLE 3 BKGD+PST
— The specified up/down converter is locked to the
Back Preset bus pair on MLE 3.
~
MLE 3 KEY 1
— The specified up/down converter is locked to the Key 1
Video + Alpha bus pair on MLE 3.
~
MLE 3 KEY 2
— The specified up/down converter is locked to the Key 2
Video + Alpha bus pair on MLE 3.
~
MLE 3 Util
— The specified up/down converter is locked to the Utility 1
Video + Alpha bus pair on MLE 3.
~
Aux Buses
— All Aux Buses not assigned to external devices are listed and
available for locking.
The middle portion of the menu screen shows a summary of your settings. As you use the
Converter
knob to scroll through the various Aux Buses with up/down converters connected to them, their
settings will be displayed in this area of the menu screen
This completes the procedure to lock an up/down converter to a bus pair.
Displaying Available Converters
You can configure your Synergy Q/MD switcher to display the number of free up/down converters in
the
Fade To Black
Display. The number displayed reflects the total number of available converters
(without regard to Bus Disabling, Converter Locking, or conversion formats). This is an optional step
that does not need to be performed but you may find it convenient to have the number of free up/down
converters displayed on your switcher panel.
Use the following procedure to display the number of free up/down converters in the
Fade To Black
Display:
1. Navigate to the
Personality Menu
as follows:
•
Press
HOME
B
MORE
B
Setup
B
Personality
.
2. Use the
Option
knob to select
FTB Display
.
3. Use the
Value
knob to select the desired setting for the
Fade To Black
Display. You can
choose between the following:
•
SmrtConv
— The
Fade To Black
Display shows the number of available
up/down converters.
•
FTB
— The
Fade To Black
Display shows the standard fade to black frames
display.
This completes the procedure to display the number of free up/down converters in the
Fade To Black
Display.
Note
It is possible to lock multiple up/down converters to the same bus pair.
This is useful if you wish to have converters of different format types
always available to a certain bus pair. You should always lock at least
two converters to a bus pair to ensure that both buses in the pair have
access to a converter at the same time.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...