1–12 • Introduction
Synergy Q/MD Engineering Manual (v9.1 MD)
The
Synergy 1.5 Q/MD
program/preset MLE is easily upgradeable to a full MLE at a later date.
However, the
Synergy 2.5 Q/MD
is not, as it requires switching to the larger Q/MD-X frame.
Advanced Copy and Swap Functions
The following convenient copy and swap functions are available as standard:
•
Copy MLE
— allows you to copy the contents of an MLE to another MLE location on
the switcher.
•
Copy/Swap Key
— allows you to copy or swap the contents of a keyer with another key
location (in the same MLE, or on a different MLE).
•
Copy Matte
— allows you to copy the contents of a matte generator to any other matte
location.
•
Copy Wipe
— allows you to copy a wipe pattern (and all wipe pattern modifiers) from
one MLE to another.
Pattern Generators
Each switcher includes, as standard, both advanced and additional pattern generators that are used for
wipe transitions and preset patterns:
•
Synergy 1 and 1.5 Q/MD:
Two advanced and two additional
•
Synergy 2 and 2.5 Q/MD:
Four advanced and four additional
Half of the advanced generators are used for wipe transitions and PST PATT 1, while the other half are
used for PST PATT 2. The additional pattern generators are used for wash generators that are available
as MLE inputs or anywhere a matte is used.
The advanced wipe generators come equipped with classic, matrix, rotary, heart, and star wipes. All
wipe types can be rotated, bordered, and repositioned. The additional wipe generators are identical to
the advanced wipe generators except that matrix capability has been removed.
Matte Generators
Each full MLE has three simple color generators and two complex ones capable of multi-color
washes. Any one of the color generators can be assigned to
COLOR BKGD1
or 2, key fill 1 or 2, key
border 1 or 2, or wipe pattern edges. Each full MLE has its own dedicated
COLOR BKGD
video
inputs to make memory recalls of individual MLEs simple and predictable.
FlexiClean™ Clean Feed Outputs
Each MLE can have its own fully programmable clean feed output. This provides a second “program”
output that is derived from a different location than the standard program output. Typical applications
include:
•
Bilingual and live-to-tape productions
•
Recording shows for later airing without “call in” phone numbers inserted.
The clean feed output can come from before or between the keyers in the MLE. Each MLE has its
own, independently configured clean feed output separate from all other clean feed outputs.
The diagram below illustrates the clean feed output configurations available on the
Synergy 1 Q/MD
with the
MultiDSK (DSK 1 and DSK 2)
option
installed.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...