6–2 • Software Upgrades and Options
Synergy Q/MD Engineering Manual (v9.1 MD)
Network Setup
This section provides instructions for configuring your network setup for your Synergy Q/MD system
software. Before proceeding, refer to Appendix C, “
IP and Web Issues
”, to familiarize yourself with
some Ethernet security considerations.
Software upgrades are performed from a computer using the
LAN 1
Ethernet port on the rear of the
Synergy Q/MD frame. Prior to performing the upgrade, it is necessary to configure the network setup
for the Synergy Q/MD switcher.
Use the following procedure to configure the network setup of your switcher:
1. Ensure that the switcher is connected to your local network.
2. Navigate to the
Setup Menu 2-2
as follows:
•
Press
HOME
B
MORE
B
Setup
B
MORE
.
3. Press
Network Setup
to display the
Network Setup Menu
.
Network Setup Menu — DHCP On
4. Set the IP Address as follows:
•
Use the
Address
knob to select
IP Address
.
•
Enter the IP Address using the keypad in the
Global Memory System
group or
with a PS/2 keyboard attached to your switcher. If you use the keypad, press
ENTER
to move between fields as there is no decimal (.) key.
5. Set the Subnet Mask as follows:
•
Use the
Address
knob to select
Subnet Mask
.
•
Enter the Subnet Mask using either the
Global Memory System
keypad or a PS/2
keyboard attached to your switcher. If you use the keypad, press
ENTER
to move
between fields.
Important
If DIP Switch 1 on the frame CPU board is set to
ON
, the network IP
address is forced to 192.168.1.1 and the netmask to 255.255.0.0.
Network changes will still take effect but a warning message will be
displayed and if you restart the switcher with DIP Switch 1 still
ON
,
the network address will revert to 192.168.1.1 and the netmask to
255.255.0.0. Refer to the section “
more information.
Note
Do not us an IP address in the range 169.254.
X
.
X
to avoid conflicts
with some of the internal boards and cards in the frame. Ross Video
recommends using an IP address in the range of 10.0.
X
.
X
for static
addressing.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...