10–24 • Custom Controls
Synergy Q/MD Engineering Manual (v9.1 MD)
MLE 2
and
MLE 2
is re-entered onto
MLE 3
, the
Active MLE Trans
custom
control will perform a transition on
both
MLE 1
and
MLE 2
.
7. Press
Insert
to insert the selected command into the custom control and display the
Insert Special Menu
1-2
.
8. Insert additional commands if needed. When you have finished inserting commands,
proceed to the next step to complete the procedure.
9. Press
UP ONE
to display the
Recording Menu
.
Custom Controls — Recording Menu
10. Press
Finish Recording
to finish recording to the selected custom control. The custom
control button will stop flashing.
This completes the procedure for creating an automation custom control macro.
Go To Menu
Use
Go To Menu
to create custom controls that automatically display Squeeze & Tease MD menus.
You must be flying a key when you run the custom control for the Squeeze & Tease MD menu to
display.
Use the following procedure to create a Squeeze & Tease MD
Go To Menu
custom control macro:
1. Navigate to the
Custom Controls Menu 1-2
as follows:
•
Press
HOME
B
Custom Controls
.
2. Select the custom control button you want to record to as follows:
•
Use the
Bank
knob to select the custom control bank you want to record the custom
control to.
•
Use the
Button
knob
to select the custom control button that you want to record a
custom control macro to. You can also press the desired button
directly
on the
control panel. Remember that buttons marked with an asterisk (*) or an (@) in the
list have already been programmed.
3. Press
Start Recording
to display the
Recording Menu
.
Important
If you have more than one re-entry set up for a shot, the
Active MLE
Trans
custom control will transition all on-air
MLEs
. If you have an
MLE
re-entered onto the
BKGD
bus of another
MLE
, the
Active
MLE Trans
custom control will transition the
MLE
re-entry with
whatever you have selected on the
PST
bus of that
MLE
.
Operating
Tip
As a recommendation, keep special functions grouped together on
your
physical
custom control buttons.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...