4–14 • Preliminary Cabling and Video Installation
Synergy Q/MD Engineering Manual (v9.1 MD)
Shutting Down the Switcher
This function shuts down the switcher, placing the CPU Board into a hibernation mode. In this mode it
is safe to turn off all your power supplies and remove the CPU Board.
Use the following procedure to shutdown the switcher:
1. Navigate to the
System Shutdown Menu
as follows:
•
Press
HOME
B
MORE
B
System Shutdown
.
System Shutdown Menu
2. Press
Shut Down
.
The system will prompt you to confirm the shutdown. Once confirmed, the frame will
shut down.
This completes the procedure for shutting down the switcher.
Powering Off the Switcher
Once your switcher has been shut down, it is safe to turn the power off.
Use the following procedure to power off your switcher:
1. Look for the flashing status indicators on the front of the switcher frame next to the
embossed Ross logo. If the indicators are not flashing between green and amber,
do not
proceed with this procedure. Refer to the section “
page 4-14 for information on shutting down your switcher.
2. Remove the switcher frame door. Refer to the section “
” on page 3-16 for information on removing the frame door.
3. Turn off the
Primary
and (if installed) the
Redundant
power switches.
Important
Do not turn the switcher frame power off until you have completed this
shutdown procedure or you may damage the hard disk.
Caution
Even though the switcher has been shut down, the power supplies are
still active
until they have been physically switched off.
Important
The Frame Door must be re-installed on the frame for proper cooling
when your switcher is running. Leaving the frame door off may cause
the Frame to overheat.
Содержание Synergy MD
Страница 1: ...Ross Video Limited Synergy Q MD Engineering Manual Volume I Software Issue 9 1 MD ...
Страница 10: ......
Страница 18: ...viii Contents Synergy Q MD Engineering Manual v9 1 MD ...
Страница 46: ...1 28 Introduction Synergy Q MD Engineering Manual v9 1 MD ...
Страница 204: ...7 34 BNC Configuration and Check Synergy Q MD Engineering Manual v9 1 MD ...
Страница 302: ...10 56 Custom Controls Synergy Q MD Engineering Manual v9 1 MD ...
Страница 366: ...13 16 SmartConversion Synergy Q MD Engineering Manual v9 1 MD ...
Страница 370: ...GL 4 Glossary of Terms Synergy Q MD Engineering Manual v9 1 MD ...