Synergy Q/MD Engineering Manual (v9.1 MD)
System Architecture • 2–15
If you were operating the switcher in
720p 59.94 Hz
, the default MLE rate is set at
30
Frames
.
Since the frequency for a progressive scan format is shown in frames, no conversion is required. By
comparing the transition rate (
30
frames) and the video format frame frequency (
60
frames per
second) you can calculate that the transition rate is
½
a second.
Important
When you switch reference formats, you must perform a soft reset
(
ALL
+
ALL
) in order to load the default rates for the format you have
set.