Chapter 5 User Screens
5.1 Tailoring/Setting Your Screens
You can tailor your monitor
’
s screens by setting
:
Background theme and color in which each measurement
’
s numerics and waveform are displayed.
Display Views
5.1.1 Changing the Display Theme
Select
“
Menu
”
→
“
Color Settings
”
.
Press “Details”, then the color setting window for each parameter will pop up.
Principal:
to enter into the setting form for parameter and number. 112 kinds of color for option with code 0~111,
one code indicates one color.
Theme:
to select the monitor’s color theme, options are: Space background, Sky blue, International fashion, and
Bamboo lands in China.
Param BKG Color A and B:
set the background color in parameter panels. Using color A and color B as the parameter’s
background color displayed by turns. The default setting for A and B is 0. The setting range is from 0 to 85, one number
indicates one color. If the background color for the first parameter panel is color A, then the second parameter panel
will be color B, and third will be color A again, alternately displayed in this way.
1) Quick Color Settings:
In the drop-down box “
” to select the different theme, so as
to change colors of all items in a view. Options are: Space background, Sky blue, International fashion, and Bamboo lands
in China.
5.1.2 Changing the Color of Waveforms and Parameter
1) Parameter Number Color Settings:
To set the parameter (ECG, S-T, SpO
2
, RESP, TEMP and NIBP etc.) information and the waveform color. Procedures are:
Locate the cursor on the color box, rotate the Navigation Knob, and select the color.
The ECG color setting for theme, waveform and number: setting range is 0~111, the default is 16.
The S-T color setting for number: setting range is 0~111, the default is 14.
The SpO
2
color setting for theme, waveform and number: setting range is 0~111, the default is 2.
The RESP color setting for theme, waveform and number: setting range is 0~111, the default is 108.
The TEMP color setting for number: setting range is 0~111, the default is 111.
The NIBP color setting for number: setting range is 0~111, the default is 28.
The CO
2
color setting for number: setting range is 0~111, the default is 108.
The CSI color setting for number: setting range is 0~111, the default is 64.
Содержание 35306
Страница 2: ...2 ENGLISH Patient Monitor Operator s Manual ...
Страница 21: ...21 ENGLISH Series III Front view Rear view Left view Right view 11 ...
Страница 22: ...22 ENGLISH Series IV Front view Rear view Left view Right view 11 Extended Module ...
Страница 128: ...128 ENGLISH Oxygenation calculation Calculate result Oxygenation calculation Reference range Unit Result Range ...
Страница 171: ...2 ESPAÑOL Monitor de paciente Manual de operador ...
Страница 189: ...20 ESPAÑOL Serie III Vista delantera Vista posterior Vista lateral izquierda Vista lateral derecha 11 ...
Страница 190: ...21 ESPAÑOL Serie IV Vista delantera Vista posterior Vista lateral izquierda Vista lateral derecha 11 Módulo adicional ...
Страница 343: ...2 FRANÇAIS Moniteur patient Manuel d utilisation ...
Страница 361: ...20 FRANÇAIS Série II Vue de face Vue arrière Connecteur et icône Vue de gauche Vue de droite 13 12 ...
Страница 362: ...21 FRANÇAIS Série III Vue de face Vue arrière Vue de gauche Vue de droite 11 ...
Страница 363: ...22 FRANÇAIS Série IV Vue de face Vue arrière Vue de gauche Vue de droite Panneau avant 11 Module avancé ...
Страница 519: ...2 ITALIANO Monitor Paziente Manuale d Uso ...
Страница 538: ...21 ITALIANO Serie III Vista anteriore Vista posteriore Lato sinistro Lato destro 11 ...
Страница 539: ...22 ITALIANO Serie IV Vista anteriore Vista posteriore Lato sinistro Lato destro 11 Modulo esteso ...